Gegote omhulsel stroombreker
Tegniese parameters
Produk Naam | Spesifikasies | Gegradeerde stroom |
MCCB | M1-63L/3300 | 10、16、20、25 |
MCCB | M1-63M/3300 | |
MCCB | M1-63M/4300A | |
MCCB | M1-63M/4300B | |
MCCB | M1-125L/3300 | 16A 20A 25A 32A |
MCCB | M1-125L/4300A | |
MCCB | M1-125L/4300B | |
MCCB | M1-125M/3300 | |
MCCB | M1-125M/4300A | |
MCCB | M1-125M/4300B | |
MCCB | M1-250L/3300 | 125A 140A 160A |
MCCB | M1-250L/ 4300A | |
MCCB | M1-250L/ 430OB | |
MCCB | M1-250M/3300 | |
MCCB | M1-250M/4300A | |
MCCB | M1-250M/4300B | |
MCCB | M1-400/3300 | 225A 250A 315A |
MCCB | M1-400/4300A | |
MCCB | M1-400/4300B | |
MCCB | M1-630/3300 | 400A 500A 630A |
MCCB | M1-630/4300A | |
MCCB | M1-630/4300B | |
MCCB | M1-800/3300 | 630A 700A 800A |
MCCB | M1-800/4300A | |
MCCB | M1-800/4300B | |
MCCB | 1-1250/3300 | 1000A 1250A |
MCCB | M1-1250/4300 | |
MCCB | M1-1600/3300 | 1600A |
MCCB | M1-1600/4300 |
Produk Naam | Spesifikasies | Gegradeerde stroom |
LMCCB | M1LE-125/3300 | 16-125A |
LMCCB | M1LE-125/4300A | |
LMCCB | M1LE-125/4300B | |
LMCCB | M1LE-250/3300 | |
LMCCB | M1LE-250/4300A | 100-250A |
LMCCB | M1LE-250/4300B | |
LMCCB | M1LE-400/3300 | 225-400A |
LMCCB | M1LE-400/4300A | |
LMCCB | M1LE-400/4300B | |
LMCCB | M1LE-630/3300 | 400-630A |
LMCCB | M1LE-630/4300A | |
LMCCB | M1LE-630/4300B | |
LMCCB | M1LE-800/3300 | 630-800A |
LMCCB | M1LE-800/4300A | |
LMCCB | M1LE-800/4300B | |
LMCCB | NM1L-1250/4300 | |
LMCCB | NM1L-1600/4300 |
Produk Naam | Spesifikasies | Gegradeerde stroom |
EMCCB | M1E-125M/3300 | 16-125A |
EMCCB | M1E-125M/4300A | |
EMCCB | M1E-125M/4300B | |
EMCCB | M1E-250M/3300 | 100-250A |
EMCCB | M1E-250M/4300A | |
EMCCB | M1E-250M/4300B | |
EMCCB | M1E-400M/3300 | 200-400A |
EMCCB | M1E-400M/4300A | |
EMCCB | M1E-400M/4300B | |
EMCCB | M1E-630M/3300 | 400A-630A |
EMCCB | M1E-630M/4300A | |
EMCCB | M1E-630M/4300B | |
EMCCB | M1E-800M/3300 | 630-800A |
EMCCB | M1E-800M/4300A | |
EMCCB | M1E-800M/4300B |
AANSOEK
M1-reeks van gegote omhulsel-stroombreker is een van ons nuwe tipe produkte wat ontwikkel en vervaardig word deur internasionale gevorderde tegnologie aan te neem.Dit word voorsien van nominale isolasiespanning 800V en word gebruik vir stroombaan van AC50/60Hz, nominale bedryfspanning AC 400V.(of minder), nominale bedryfsstroom tot 1600A vir ongereelde omskakeling en aansit van die motors.
Toegerus met die beskermingstoestelle vir oorstroom, kortsluiting en onderspanning, is die produkte in staat om skade aan stroombane en toevoereenhede te voorkom.
Die produkte voldoen aan GB14048.2, IEC60947-2 sterre.
SOORTE EN BETEKENIS
Let wel:*Geen kode vir verspreidingbrekers nie;"2" verteenwoordig motorbeskermingstroombrekers.
*Geen kode vir direkte handvatselwerking nie; "P" verteenwoordig elektriese werking, en "Z" verteenwoordig roterende handvatsels.
*Gegradeerde breekvermoë graad van MCCB, C-Ekonomiese tipe L-Stard en tipe M-Middel hoë breekvermoë tipe, H-Hoë breekvermoë tipe.
KLASSIFIKASIE VAN MCCB
Volgens produkpale word twee soorte drie- en vierpool voorsien. Die neutrale paal (N-paal) van vier pool het vier tipes:
Tipe A: Geen huidige trip-release op N paal wat die hele tyd maak;nie toemaak en oopmaak met die ander drie pale nie.
Tipe B: Geen stroomvrystelling op N-paal wat toe- en oopmaak met die ander drie pale.
Tipe C: Met huidige trip-release op N paal wat toemaak en oopmaak met die ander drie pale.
Tipe D: Met huidige trip-release op N paal wat die hele tyd maak;nie toemaak en oopmaak met die ander drie pale nie.
HOOF TEGNIESE SPESIFIKASIES
Tik | Gegradeer | Paal | Gegradeer | Gegradeer | Arcing-Over | Uiteindelike kort | Diens Kort | Operasie | |
ON | AF | ||||||||
M1-63S | 6,10,16,20,25 | Drie | 500V | 400V | 0 | 25 | 18 | 1500 | 8500 |
M1-63H | 0 | 50 | 35 | ||||||
M1-100L | 10,16,20 | 800V | 0 | 25 | 18 | ||||
M1-100S | 0(≤50) | 35 | 22 | ||||||
M1-100H | 0(≤50) | 50 | 35 | ||||||
M1-100R | 0(≤50) | 85 | 50 | ||||||
M1-225L | 100 125 | ≤50 | 25 | 18 | 1000 | 7 000 | |||
M1-225S | ≤50 | 35 | 22 | ||||||
M1-225H | ≤50 | 50 | 35 | ||||||
M1-225R | ≤50 | 85 | 50 | ||||||
M1-400L | 225 250 | ≤50 | 35 | 25 | 1000 | 4000 | |||
M1-400S | ≤50 | 50 | 35 | ||||||
M1-400H | ≤100 | 65 | 42 | ||||||
M1-630L | 400 | ≤100 | 35 | 25 | |||||
M1-630S | ≤100 | 50 | 35 | ||||||
M1-630H | ≤100 | 65 | 42 | ||||||
M1-630R | ≤100 | 100 | 65 | ||||||
M1-800H | 630 700 | ≤100 | 75 | 50 | |||||
M1-800R | ≤100 | 100 | 65 | ||||||
M1-1250H | 800 1250 | Drie | ≤100 | 100 | 65 | ||||
M1-1600H | 1250 100 | ≤100 | 100 | 65 |
OORSIG EN INSTALLASIE-DIMENSIES
Tik | Omlyn afmetings (mm) | Installasie | |||||||||||||||||||
Voorpaneel aansluiting | |||||||||||||||||||||
W | W1 | L | L1 | L2 | H | H1 | H2 | H3 | H4 | C | D | E | F | G | I | W2 | W3 | A | B | Φd | |
M1-63S | 76 | 50 | 135 | 170 | 117 | 7 | 4 | 85 | 28.5 | 48 | 22 | 14 | 7.5 | 100 | 75 | 25 | 117 | 3.5 | |||
M1-63H | 76 | 50 | 135 | 170 | 117 | 82 | 98,5 | 28 | 7 | 4 | 85 | 28.5 | 48 | 22 | 14 | 7.5 | 100 | 75 | 25 | 117 | 3.5 |
M1-100L | 92 | 60 | 150 | 185 | 132 | 68 | 86 | 24 | 7 | 4 | 88 | 35,5 | 50 | 22 | 17.5 | 7.5 | 30 | 129 | 4.5 | ||
M1-100S | 92 | 60 | 150 | 185 | 132 | 68 | 86 | 24 | 7 | 4 | 88 | 35,5 | 50 | 22 | 17.5 | 7.5 | 30 | 129 | 4.5 | ||
M1-100H | 92 | 60 | 150 | 185 | 132 | 86 | 104 | 24 | 7 | 4 | 88 | 35,5 | 50 | 22 | 17.5 | 7.5 | 122 | 90 | 30 | 129 | 4.5 |
M1-100R | 92 | 60 | 150 | 185 | 132 | 86 | 104 | 24 | 7 | 4 | 88 | 35,5 | 50 | 22 | 17.5 | 7.5 | 30 | 129 | 4.5 | ||
M1-225L | 107 | 70 | 165 | 215 | 144 | 86 | 110 | 24 | 5 | 4 | 102 | 31.5 | 50 | 22 | 17 | 9 | 35 | 126 | 5 | ||
M1-225S | 107 | 70 | 165 | 215 | 144 | 86 | 110 | 24 | 5 | 4 | 102 | 31.5 | 50 | 22 | 17 | 9 | 35 | 126 | 5 | ||
M1-225H | 107 | 70 | 165 | 215 | 144 | 103 | 127 | 24 | 5 | 4 | 102 | 31.5 | 50 | 22 | 17 | 9 | 142 | 105 | 35 | 126 | 5 |
M1-225R | 107 | 70 | 165 | 215 | 144 | 103 | 127 | 24 | 5 | 4 | 102 | 31.5 | 50 | 22 | 17 | 9 | 35 | 126 | 5 | ||
M1-400L | 150 | 96 | 257 | 357 | 224 | 105 | 155 | 38 | 8 | 6 | 128 | 64,5 | 89 | 65 | Φ26 | 44 | 194 | 7 | |||
M1-400S | 150 | 96 | 257 | 357 | 224 | 105 | 155 | 38 | 8 | 6 | 128 | 64,5 | 89 | 65 | Φ26 | 198 | 144 | 44 | 194 | 7 | |
M1-400H | 182 | 116 | 270 | 370 | 234 | 110 | 160 | 43 | 8 | 6 | 134 | 70 | 89 | 65 | Φ29 | 58 | 200 | 7 | |||
M1-630L | 182 | 116 | 270 | 370 | 234 | 110 | 160 | 43 | 8 | 6 | 134 | 70 | 89 | 65 | Φ29 | 58 | 200 | 7 | |||
M1-630S | 182 | 116 | 270 | 370 | 234 | 110 | 160 | 43 | 8 | 6 | 134 | 70 | 89 | 65 | Φ29 | 240 | 174 | 58 | 200 | 7 | |
M1-630H | 182 | 116 | 270 | 370 | 234 | 110 | 160 | 43 | 8 | 6 | 134 | 70 | 89 | 65 | Φ29 | 58 | 200 | 7 | |||
M1-630R | 210 | 140 | 280 | 380 | 243 | 106 | 145 | 33 | 30 | 128 | 70 | 243 | 7.2 | ||||||||
M1-800H | 210 | 140 | 280 | 380 | 243 | 106 | 145 | 33 | 30 | 128 | 70 | 243 | 7.2 | ||||||||
M1-800R | 210 | 140 | 280 | 380 | 243 | 106 | 145 | 33 | 30 | 128 | 70 | 243 | 7.2 | ||||||||
M1-1250H | 140 | 393 | 200 | ||||||||||||||||||
M1-1600H | 140 | 393 | 200 |
Bykomstige kode | Bybehore Naam |
200、300 | Geen |
208、308 | Alarm kontak |
210、310 | Shunt Release |
220、320 | Hulpkontak |
230、330 | Onderspanningvrystelling |
240、340 | Shunt release-hulpkontak |
250、350 | Shunt release Onderspanning Release |
260、360 | Twee groepe hulpkontak |
270、370 | Hulpkontak onderspanningvrystelling |
218、318 | Shunt Release Alarm Kontak |
228、328 | Hulpkontakalarmkontak |
238、338 | Onderspanningvrystelling-alarmkontak |
248、348 | Shunt Release, Aux Contact, Alarm Kontak |
268、368 | Twee groepe hulpkontak,Alarm kontak |
278、378 | Aux-kontak, onderspanningvrystelling, alarmkontak |
BESKERMINGSKENMERKE
Die termodinamiese vrystelling van 'n stroombreker bied die kenmerk van omgekeerde tydsvertraging, terwyl die magnetiese vrystelling die oombliklike werking is soos getoon op tabel 4 (verspreidingstroombreker).
Gegradeerde stroom | Termodinamiese vrystelling | Operasioneel | |
1.05In (koue toestand) | 1.30In (hitte toestand) | ||
10≤In≤63 | ≥1 | <1 | 10In±20% |
63 | ≥2 | <2 | |
100 | ≥2 | <2 | 10In±20% |
800 | ≥2 | <2 | 10In±20% |
WERKSOMGEWING
(1) Hoogte≤2000m.
(2) Omgewingstemperatuur: +40 ℃ (+45 ℃ vir skepe) ~ -5 ℃.
(3) Weerstand teen vog.
(4) Weerstand teen sout- en olie-sparry.
(5) Weerstand teen vorm.
(6) Weerstand teen kernstraling.
(7) Maksimum salant:?2.5?
(8) Betroubare werk onder aardbewing toestand(4g).
(9) Omringende omgewing wat vry is van uitsonderlike gevaar en lug of stof wat korrosie van metaal of swakheid van isolasie kan veroorsaak.
(10) Omringende omgewing vry van erosie van reën of sneeu.